У нас вы можете посмотреть бесплатно Design requirement for Substation Civil & Structure или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
DESIGN REQUIREMENT FOR SUBSTATION CIVIL & STRUCTURE Explaining Design requirements such as: 1. Input for Design Engineering for Civil and Structure 2. Standard codes: American, European, Russian, BS, BIS, ISO, IEEE… 3. Software and tools: ETAB, SAFE, Robot, STAAD.pro, AutoCAD, Advance Steel, Tekla Structures, Navisworks… RELATED VIDEOS: Design of Substation Gantry structure | Eurocode | Robot Structural Analysis | | STAGE 1 of 3: [Primary load application to Model] : • Design of Substation Gantry structure | Eu... | STAGE 2 of 3: [Load combinations application to Model] : • Design of Substation Gantry structure | Eu... "EN 50341-1 | Substation Gantry Structure loads | | STAGE 1 of 6 [Temperature, Reliability level, and Wind parameter, Wind pressure and Ice parameter, Mean and Gust wind and its response factors, Structural Resonance factors, Drag Coefficient ] : • EN 50341-1 | Substation Gantry Structure l... | STAGE 2 of 6 [Temperature, Reliability level, and Wind parameter, Wind pressure and Ice parameter, Mean and Gust wind and its response factors, Structural Resonance factors, Drag Coefficient ]: • EN 50341 1 Substation Gantry Structure lo... | STAGE 3 of 6 [Wind Pressure & forces on Components: Conductor, Earth wire, Structure, Insulator, Equivalent ice covered diameter of wires]: • EN 50341-1 | Substation Gantry Structure l... | STAGE 4 of 6 [Primary Loads and Load combinations]: • EN 50341-1 | Substation Gantry Structure l... | STAGE 5 of 6 [Dead Load without ice, Dead Load with ice, Wire tensions without deviation, Temperature 0, -20 and Tmin and Wire tensions with deviation, Temperature 0, -20 and Tmin]: • EN 50341-1 | Substation Gantry Structure l... | STAGE 6 of 6 [Extreme Wind, High Wind + Ice, Moderate Wind + Ice and Short Circuit Forces]: • EN 50341-1 | Substation Gantry Structure l... Modelling Substation Gantry structure | STAAD.Pro | | STAGE 1 / 3 |: Introduction, Principle drawing, Contents, Reference to Substation Philosophy, Tower: Node and Member creations, Support condition: • Modelling Substation Gantry structure STA... | STAGE 2 / 3 |: Tower: Member Grouping, Renumbering Members, Member properties, size, Member Beta angle position: • Modelling Substation Gantry structure | ST... | STAGE 3 / 3 |: Girder: Adding main legs, Segments, Adding cross bracings, Tie members, Member groupings and definition, Assigning Truss member properties, Addition bays or extension of gantry structure: • Modelling Substation Gantry structure | ST... Modelling Substation Gantry structure | Robot Structural Analysis | | STAGE 1 of 3 [Principle drawing, Reference to Substation Philosophy, Job preference: UOM, Standards for Load, Material and Design, Tower: Node, Member creations, Segments & Support conditions.] : • Modelling Substation Gantry structure Robo... | STAGE 2 of 3 [Structure Window view icons (To view node, Member Numbers, Local System, Support views), Tower modelling [Adding Cross Bracing Members, Member Grouping, Renumbering Members, Member properties, size, Dummy Member properties, Member Gamma angle position] : • Modelling Substation Gantry structure | Ro... | STAGE 3 of 3 [Girder (Adding main legs, Segments, Adding cross bracings, Tie members, Member groupings and definition), Assigning Truss member properties, Addition bays or extension of gantry structure & 3D Views] : • Modelling Substation Gantry structure | Ro... OTHER RELATED VIDEOS: | Transmission line Towers | Design Philosophy: • Transmission line Towers | Design Philosophy | Substation Civil and Structure: • Substation Civil and Structure | Design requirement for Substation Civil & Structure: • Design requirement for Substation Civil & ... | Substation Gantry Structure | Design Philosophy: • Substation Gantry Structure | Design Philo... | Load calculations (Wind and Seismic): https://www.youtube.com/watch?v=b3w5H... ------------------------------------------------------------------------------------------------------------------------------------------------------