У нас вы можете посмотреть бесплатно Testing an RTD Input Temperature Transmitter With The Fluke 754 Documenting Process Calibrator или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
http://bit.ly/2DE9xsR This video demonstrates the steps to calibrate an RTD input temperature transmitter with the Fluke 754 Documenting Process Calibrator. 1. Press the Measure mA button and turn on Loop Power 2. Press the TC/RTD button and select RTD 3. Scroll through the list of RTDs and select the appropriate instrument 4. Input in the temperature 5. Press the MEASURE/SOURCE button to document the calibration 6. Press F1 to document the calibration As Found 7. Configure the test to your desired settings 8. Once finished configuring the test, press F2 to begin Auto Test 9. Done Whether you're calibrating instruments, troubleshooting a problem, or running routine maintenance, the Fluke 754 with HART® communication can help you get the job done faster. It does so many different tasks, so quickly and so well, it's the only process calibrator you need to carry. This rugged, reliable integrated communicating calibrator is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 is a power multifunction documenting calibrator that you can use to download procedures, lists, and instructions created with software; or upload data for printing, archiving, and analysis. The powerful built-in HART interface is capable of performing nearly all the day-to-day tasks you now perform with a separate communicator. In fact, the 754 does the work of several tools. It sources, simulates and measures pressure, temperature, and electrical signals with one rugged, hand-held device. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Plus, the new improved graphical screen, Li-Ion battery for longer life, USB port, and accessories help you work smarter and faster. Some key features include: • Measures volts, mA,TDs, thermocouples, frequency, and ohms to test sensors, transmitters and more • Sources/simulates volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters • Powers transmitters during test using loop supply with simultaneous mA measurement For more information about the Fluke 754 Documenting Process Calibrator, visit the Fluke website here: http://bit.ly/2DE9xsR