Calibration and measurement http://www.ligra.it/?s=motic&post_typ... We recommend using the following chart when using the stitch size to use to calibrate each lens. The choice depends on a second part the camera is connected to the microscope. For each microscope objective or for each frozen still image of the stereomicroscope, separate calibrations are necessary. Prepare the calibration Adapt to the window: flag the "Fit to window" box. The point of the state slide should be completely visible in the image area. Exposure time: adjusting the exposure time is a contrast to the background. White balance: set the white balance manually to ensure accurate representation. Click here to close the mouse and click on "White balance" calibrate Go to "Advanced Settings". Click on "Calibration". Measure the used lens and the diameter of the point and calibrate. Thank you that the healthy circle is completely green. Type of irregularity, the measurement is not correct! And you will need to make the necessary adjustments so that you get a perfect perfect! Now you can dare to name a target that has been calibrated. Save that you have flagged the "Zoom" square and save the evaluation. Close the repair window. Now we take a picture. This click to make measurements This step is necessary to export the recording. Use the table for verification and control Open the calibration table. For a clearer view of the list of objectives, from here are listed the default software, a part called "From_Host". Now select the calibration just created "Motic 4X" and click on "OK". Flag "scalebar" and click on "Settings". Imagine the data of the diameter of the point and choose a visible color. The horizontal and vertical scales on the screen must coincide with the diameter of the point. This is a simple way for revenue that accuracy is correct. Measurements on images taken Open an image taken with a lens that has been calibrated. Click "Measure" in the control panel. Check the target from the calibration list. "Motic 4X" is automatically transferred here. To perform the calibration, you need to take an image after calibrating it. View the required precision unit and select the accuracy. Click on "Measure" at the top of the menu and select one of the different measurement options. You can preview the complete image with the right mouse button and select "Fit to window". Click on "Measure to window" to return to the normal window. The measurements are displayed on "Measure table" and can be exported to an external file.