У нас вы можете посмотреть бесплатно Tined Lead Procedure | Axonics SNM System® или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
Are bladder or bowel control symptoms disrupting your life? You are not alone. Millions of people worldwide suffer from these life-altering symptoms. Regain control of your life. Discover the Axonics System. Go to www.FindRealRelief.com to learn more! Sacral Neuromodulation is a guideline-recommended therapy that restores normal control of the bladder and bowel. Axonics Sacral Neuromodulation Therapy provides gentle stimulation to the nerves that control the bladder and bowel. The stimulation can restore normal communication between the brain and the bladder and bowel, which can result in an improvement of your symptoms, whether you are suffering from overactive bladder, bowel incontinence, or urinary retention. To determine if Sacral Neuromodulation is the right treatment option for you, it is important to consult with your doctor. This animation demonstrates the Axonics Tined Lead Procedure, in preparation for either an Advanced Trial, or a Full Implant of the Axonics System. Definitions: CP = Clinician Programmer INS = Implantable Neurostimulator Chapters: 00:00 - Introduction 00:10 - Mark Patient Pre-operatively 00:42 - Patient Positioning 01:05 - Connect Ground Pad 01:17 - Identify Third Sacral Foramina 01:11 - Insert Foramen Needle 01:40 - Mark Medial Aspect 02:01 - Insert Foramen Needle 02:50 - Connect Needle Test Stim Cable 03:00 - Use CP to Test for Responses 03:22 - Place Directional Guide 03:33 - Remove Foramen Needle 03:37 - Insert Introducer Sheath & Dilator 03:53 - Remove Dilator & Directional Guide 04:00 - Insert Tined Lead 04:42 - Readjust Tined Lead if necessary 05:02 - Tined Lead to Follow S3 Nerve 05:10 - Connect Tined Lead Stim Cable and Test 05:32 - Use CP to Confirm Responses 05:45 - Remove Introducer & Lead Stylet 06:07 - Final Tined Lead Placement 06:25 - Test Electrodes For full Important Safety Information and Indications, visit: www.axonics.com/isi IMPORTANT NOTE: This surgical technique is only intended as a guide. We recommend that the physician is properly trained before conducting the procedure. The physician should consider the individual needs of each patient and make appropriate adjustments as necessary. Please refer to the Axonics SNM product manual at https://www.axonics.com/hcp/resources... for additional information on proper use, indications, contraindications, and warnings.