Activ Screw - Ø6.5 mm cannulated and compression screws. The Activ Screw range consists of three compressive Ø6.5 mm cannulated hexalobe screws, one with a long thread, one with a short thread and a fully threaded positioning screw. An intuitive and specific kit has been designed to insert these screws. The Ø6.5 mm compression screws with a short thread of 16 mm, available in lengths from 40 mm to 120 mm, are guided in a straight line along a 2.5 mm diameter pin thanks to their cannulation. The Ø6.5 mm compression screws with a 32 mm long thread, available in lengths from 45 to 120 mm, are guided in a straight line along a 2.5 mm diameter pin thanks to their cannulation. The Ø6.5 mm positioning screws with full thread, available in lengths from 40 mm to 120 mm, are guided in a straight line along a 2.5 mm diameter pin thanks to their cannulation. These screws are not available in the Activ Screw kit; they are available separately in single-unit sterile packaging (S-box). Learn more : https://newcliptechnics.com/product-r... #medtech #surgery #medicaleducation #newcliptechnics #arthrodesis -------------------------------------------------------------------------------------------- Implants of the Stand-Alone Screws range are intended for fractures fixation, osteotomies and arthrodeses of bones in adults, appropriate for the size of the device. This medical device is a class IIb regulated health product which bears the CE mark (CE1639 SGS BE) under this regulation. These products must be handled and/or implanted by trained and qualified staff who have read the instructions for use. A surgeon must always rely on her or his own professional clinical judgement when deciding whether to use a particular product when treating a particular patient. Product availability is subject to the regulatory or medical practices that govern individual markets. Please refer to the brochure for more information about the product. Manufacturer : Newclip Technics – Activ Screw – 01/2024 - Medical device EC : class IIb – CE1639 SGS BE - Class US II Newclip Technics - 45 rue des Garottières - 44115 Haute Goulaine, France +33 (0)2 28 21 23 25 www.newcliptechnics.com