• ClipSaver
ClipSaver
Русские видео
  • Смешные видео
  • Приколы
  • Обзоры
  • Новости
  • Тесты
  • Спорт
  • Любовь
  • Музыка
  • Разное
Сейчас в тренде
  • Фейгин лайф
  • Три кота
  • Самвел адамян
  • А4 ютуб
  • скачать бит
  • гитара с нуля
Иностранные видео
  • Funny Babies
  • Funny Sports
  • Funny Animals
  • Funny Pranks
  • Funny Magic
  • Funny Vines
  • Funny Virals
  • Funny K-Pop

How to Locate Cable Faults with the Murray Loop Test скачать в хорошем качестве

How to Locate Cable Faults with the Murray Loop Test 1 year ago

murray loop test

murray loop test principle

murray loop test limitations

locate faults

cable faults

underground power cables

open circuit faults

short circuit faults

earth faults

broken conductors

insulation failure

torn cable

resistance measurement

faulted cable

exact location of fault

fault location methods

wheatstone bridge

earth fault location

short circuit fault location

Не удается загрузить Youtube-плеер. Проверьте блокировку Youtube в вашей сети.
Повторяем попытку...
How to Locate Cable Faults with the Murray Loop Test
  • Поделиться ВК
  • Поделиться в ОК
  •  
  •  


Скачать видео с ютуб по ссылке или смотреть без блокировок на сайте: How to Locate Cable Faults with the Murray Loop Test в качестве 4k

У нас вы можете посмотреть бесплатно How to Locate Cable Faults with the Murray Loop Test или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:

  • Информация по загрузке:

Скачать mp3 с ютуба отдельным файлом. Бесплатный рингтон How to Locate Cable Faults with the Murray Loop Test в формате MP3:


Если кнопки скачивания не загрузились НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу страницы.
Спасибо за использование сервиса ClipSaver.ru



How to Locate Cable Faults with the Murray Loop Test

There are 3 types of faults that are likely to occur in underground power cables. Open circuit faults occur due to broken conductors. Short circuit fault occurs due to insulation failure and earth fault occurs when the cable is torn. Since the underground cables are buried, if the fault occurs, it is invisible to our naked eye. By measuring the resistance, we can identify the faulted cable. Yes, we can find which cable has a fault. However, we cannot identify the exact location of the fault. There are several methods for locating the faults in underground cables. In this video, we are just concentrating on the Murray loop test. This is used to locate the earth fault and short circuit fault. It uses the principle of the Wheatstone Bridge. Chapters: 00:00 Intro 01:08 Wheatstone Bridge 02:13 Murray loop test for Earth fault 05:37 Murray loop test for short circuit fault 06:05 Limitation of Murray loop test

Comments
  • Cable Fault Location: From Theory to Practice 10 months ago
    Cable Fault Location: From Theory to Practice
    Опубликовано: 10 months ago
    4022
  • Using the Murray Loop Test to Locate Ground Faults 5 years ago
    Using the Murray Loop Test to Locate Ground Faults
    Опубликовано: 5 years ago
    11253
  • Tom Sandri's Ultimate 5-Hour Cable Fault Locating Course - Webinar Replay 2 years ago
    Tom Sandri's Ultimate 5-Hour Cable Fault Locating Course - Webinar Replay
    Опубликовано: 2 years ago
    2960
  • TANBOS T20 Cable Fault Location System 3 years ago
    TANBOS T20 Cable Fault Location System
    Опубликовано: 3 years ago
    4780
  • LOOP IMPEDANCE – WHY IS IT IMPORTANT - Ze and Zs – How does Loop Impedance affect my installation? 3 years ago
    LOOP IMPEDANCE – WHY IS IT IMPORTANT - Ze and Zs – How does Loop Impedance affect my installation?
    Опубликовано: 3 years ago
    62974
  • Cable Fault Locating Techniques 12 years ago
    Cable Fault Locating Techniques
    Опубликовано: 12 years ago
    54624
  • Understanding and Interpreting the Time Domain Reflectometer Traces for Cable Fault Location 3 years ago
    Understanding and Interpreting the Time Domain Reflectometer Traces for Cable Fault Location
    Опубликовано: 3 years ago
    13411
  • AEMC® - Understanding Ground Resistance Testing (3640 Discontinued Replaced by 6424) 6 years ago
    AEMC® - Understanding Ground Resistance Testing (3640 Discontinued Replaced by 6424)
    Опубликовано: 6 years ago
    377807
  • 3 Methods to Improve String Efficiency 2 years ago
    3 Methods to Improve String Efficiency
    Опубликовано: 2 years ago
    6756
  • Why Circuit Breakers DON'T Protect People (electric shocks) 1 year ago
    Why Circuit Breakers DON'T Protect People (electric shocks)
    Опубликовано: 1 year ago
    2083701

Контактный email для правообладателей: [email protected] © 2017 - 2025

Отказ от ответственности - Disclaimer Правообладателям - DMCA Условия использования сайта - TOS



Карта сайта 1 Карта сайта 2 Карта сайта 3 Карта сайта 4 Карта сайта 5