Monnal T60 is an emergency, critical care, portable ventilator for professional use. This quick user video tutorial guide is created by EO Medical in Singapore. We show step by step instructions on how to start "BiPAP" on the Monnal T60 transport ventilator, via PSV-NIV mode. Note that this tutorial applies to Monnal T60 where PI is controlled directly, instead of PS. (If your device shows "PS" in the setting, please refer to Episode 4: How to Start PSV-NIV Mode - • Monnal T60: How To Begin PSV-NIV Mode... ) Introduction: What is PSV-NIV mode? PSV = Pressure Support Ventilation. It is also known as "BiPAP" or "Bilevel" mode, where 2 levels of pressure are being delivered during spontaneous breathing. NIV = Non-Invasive Ventilation. This means that positive pressure breaths are delivered via an interface such as a mask or prongs that seals over the nose, mouth or both. In this video, we are using a non-vented oronasal mask (also known as full-face mask), brand: Respireo Hospital F NV, disposable. Step 1: Power on the device by pressing on the green button. Step 2: Select PSV-NIV mode from homescreen. Press the rotating knob firmly once more to begin PSV-NIV ventilation. Step 3: Set IPAP via "PI" key: tap on the setting. Rotate the knob to adjust value. Once adjusted, press firmly on the knob to confirm changed setting. Step 4: Set EPAP via "PEEP" key. TIMESTAMPS 0:00 Introduction 0:12 Power on 0:17 Choosing "PSV-NIV" mode 0:29 Adjusting IPAP via "PI" 0:48 Adjusting EPAP via "PEEP" See other tutorial videos in the Monnal T60 series here: Season 1 Full Playlist - • Monnal T60 Ventilator: Season 1 Episode 1: How to Setup the Ventilator for Use (without HME filter) - • Monnal T60: How to Setup the Ventilat... Episode 1.1: How to Setup the Ventilator for Use (with HME filter) - • Monnal T60: How to Set Up the Ventila... Episode 2: How to Perform an Autotest Check - • Monnal T60: How To Perform An Autotes... Episode 3: How to Start (A)VCV Mode - • Monnal T60: How To Start (A)VCV Mode ... Episode 4: How to Start PSV-NIV Mode - • Monnal T60: How To Begin PSV-NIV Mode... Episode 4.1: How to Set BiPAP via PSV-NIV Mode - • Monnal T60: How to Set BiPAP via PSV-... Episode 5: How to Select Other Ventilation Modes - • Monnal T60: How to Select Other Venti... Episode 6: How to Monitor Ventilation Parameters - • Monnal T60: How to Monitor Ventilatio... Season 2 Full Playlist - • Monnal T60 Ventilator: Season 2 Episode 1: How to Use PRVC Mode - • Monnal T60: How To Use PRVC Ventilati... Episode 2: How to Measure Plateau Pressure - • Monnal T60: How To Measure Plateau Pr... Episode 3: How to Set Up ETCO2 Measurement - • Monnal T60: How To Set Up The CO2 Mea... Episode 4: How to Use CPV Option to Ventilate Patient During Chest Compressions - • Monnal T60: How to Use CPV option to ... This material is provided as a supplementary learning tool to the User Manual. It is not intended to replace the User Manual which contains important information on ‘How to use a Product’, including safety symbols. Happy to assist! Find out more: https://eo.com.sg/product/air-liquide... Contact us: https://eo.com.sg/contact-us | Phone +65 6100 5060 Instagram: / eomedical LinkedIn: / eomedical © 2023 EO Medical Pte Ltd. All Rights Reserved.