У нас вы можете посмотреть бесплатно Seismic zones of india as per latest IS 1893 Code explained. или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
#AllAboutBridges #BridgeEngineering #BridgeDesign #BridgeConstruction #BridgeSafety #BridgeProjects #MegaBridges #BridgeMaintenance #BridgeInspection #BridgeRetrofit #BridgeRepair #BridgeCollapse #BridgeInnovation #BridgeWorld #RailwayBridge #HighwayBridge #SuspensionBridge #CableStayedBridge #ArchBridge #TrussBridge #SteelBridge #ConcreteBridge #IconicBridges #CivilEngineering #StructuralEngineering #ConstructionEngineering #EngineeringDesign #StructuralDesign #EngineeringMarvel #CivilProjects #MegaProjects #InfrastructureEngineering #SmartInfrastructure #EngineeringExplained #STEM #EngineerLife #FutureOfInfrastructure #EngineeringCommunity #ConstructionSafety #WorksiteSafety #SafetyFirst #WorkerSafety #JobsiteHazards #EngineeringFails #ConstructionFails #StructuralFailure #BuildingCollapse #Collapse #ConstructionDisaster #EngineeringDisaster #HumanError #DisasterAwareness #AccidentSimulation #Jacketing #ConcreteJacketing #BridgeRehabilitation #StructuralStrengthening #StructuralRepair #BridgeRetrofitting #SeismicRetrofitting #EarthquakeEngineering #CorrosionProtection #BridgeReinforcement #RepairAndRehabilitation #StructuralResilience #AIGenerated #AIshorts #ViralAI #EngineeringAI #SimulationVideo #DisasterSimulation #EngineeringAnimation #AIVisualization #DroneFootage #DroneView #DroneShots #DroneEngineering #Shorts #Viral #ViralVideo #ViralShorts #TrendingNow #EngineeringShorts #BridgeShorts #CivilShorts #ConstructionShorts #EngineeringViral #BridgeViral #EduShorts #TechShorts #Engineering #Civil #Structural #Construction #Building #Infrastructure #RealEstate #Crane #Worker #SafetyVest #EngineeringWorld #MegaStructures #UrbanDevelopment #TransportInfrastructure #EngineeringEducation At the top of the scale lies Zone V, classified as the very high damage risk zone. It carries a seismic zone factor of 0.36 and corresponds to intensity IX or greater on the MSK scale. The regions most at risk here include the entire Northeastern states, the Rann of Kutch in Gujarat, the Kashmir Valley, the western and central stretches of the Himalayas in Himachal Pradesh and Uttarakhand, northern Bihar, and the Andaman and Nicobar Islands. These areas demand the strictest earthquake-resistant design practices. One step below is Zone IV, considered the high damage risk zone, with a seismic zone factor of 0.24. It corresponds to intensity VIII on the MSK scale. This zone covers parts of Jammu and Kashmir, Himachal Pradesh, Uttarakhand, Sikkim, northern Uttar Pradesh, portions of Bihar and West Bengal, and even includes the National Capital Territory of Delhi, where both population density and vulnerability make seismic safety paramount. Zone III is classified as the moderate damage risk zone. It carries a seismic zone factor of 0.16 and corresponds to MSK intensity VII. Despite the word “moderate,” this zone covers a significant portion of India, stretching across parts of Kerala, Goa, Lakshadweep, remaining regions of Uttar Pradesh, Bihar, and West Bengal, and extending over large tracts of Punjab, Gujarat, Rajasthan, Madhya Pradesh, Maharashtra, Odisha, Andhra Pradesh, Telangana, Tamil Nadu, and Karnataka. In these areas, the design of structures must still incorporate earthquake-resistant features, though the demands are less stringent than in Zones IV and V. Finally, there is Zone II, which represents the low damage risk zone. With a seismic zone factor of 0.10 and an expected intensity of MSK VI or lower, this is the least seismically active classification, covering the remaining parts of the country. While the risk is reduced, the code ensures that even in these regions, structures are designed with a basic level of seismic resistance. It is important to note that India once had five seismic zones, but with the 2002 revision of IS 1893, Zones I and II were merged into a single category, leaving today’s four-zone system. This classification has been retained in the 2016 revision, which not only reaffirmed the zonation but also updated design provisions to reflect modern engineering practices. For civil and structural engineers, these zones are far more than just lines on a map. They are the foundation for safe design. The zone factor directly influences how much lateral resistance a structure must be built to provide. In the most active regions, buildings, bridges, and lifeline infrastructure must be designed with higher strength, ductility, and energy-dissipating capacity. The goal is not just to minimize damage during moderate quakes but to prevent catastrophic collapse during the strongest earthquakes. Seismic zoning, therefore, is both a scientific achievement and a practical tool. It bridges geology and engineering, ensuring that India’s structures, from homes to highways to high-rise towers, are designed to withstand the forces of nature that are written into the very fabric of the land.