У нас вы можете посмотреть бесплатно Cara pasang charger Genset или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
Charger battrey Specification list 1. Model : TB388 2. Working voltage : 110-240VAC general 3. Power Frekwensi : 50 Hz/60 Hz general 4. Drive modle : Quartz mtor type 5. Blackout compensation : 300 h (operation temperrature 20°C) 6. Time precision : poor reading +/_ 30s (operation temperature 25°C) 7. Action time precision : +/_ 3 minut (Not including initial time to adjust error) 8. Cycle : 24 hours 9. Power consumption : 110 VAC1W 220VAC2W 10. Out put contacts : (Normally Open) 11. Countact capasity 1) Resistance load : 20 A 2) Incandescent lamp load : 10 A 3) Inductivloade (cos = 0,7) : 12 A 4) Motor load : AC110.750W AC220V.1500W 12. Setting time 1) Minimum setting unit : 15 minutes 2) Minimum setting : 15 minutes 3) No.of on/off operation : 96 operations/day 13. Ambient operating temperature : -10°C to +50°C 14. Ambient operating humity : less than 85% 15. Weight : 250 g How to install (unit:mm) (1) The occasion of exposed on the surface of install and use in the ontology of two installation hole with wooden bolt to be fixed. 1. Setting the operating time Fold the setting pin inside (Off) or outside (On) at the desired time you want the action to occur. caution (1) Do not try to fold the four setting pins next to the current time display you can not set these times . if you force it, you maby damage the switch. (2) if the time you want is in this area, turn the minute in the direction shown by the arrow and then fold the setting pin. Example this occasion 1.The setting likes this at 10.00 in the morning (On) at 10.30 in the morning (Off) 2.The setting likes this 01.00 in the afternoon (On) and 2.30 in the afternoon (Off) 2) Setting the manual switch Set the manual switch to the (Auto) position. (Auto) : The output will be turned on and off at the set times. (On) : The output will be on, regardless of the settings ( countinuosly On). (Off) : The output will be off, regardless of the settings ( countinuously Off) you can use a manual switch load operation test and please set to ON or OFF position.. Caution ; please turn it to AUTO position after you finished your testing.