The EG11-150 belongs to ELGi’s EG Series of oil-lubricated rotary screw air compressors. The “11 kW” refers to motor power. Typical working pressure range for EG-series compressors is 4.5 to 12.5 bar (g) depending on model and configuration. For EG 11-150 specifically, spec sheets list its “max working pressure” around 11 bar g (or about 157 psi g) according to one source. The “NEURON II” is the controller/interface used on many ELGi compressors — it manages start/stop, pressure & temperature sensors, solenoids, safety interlocks, etc. 🛠️ How to adjust pressure “Up / Down” (i.e. setpoint changes) on Neuron II According to the Neuron II manual: The controller has a menu-based interface on an LCD plus arrow buttons (Up/Down, Left/Right), and Enter/OK and Escape buttons. To change a parameter (for example pressure setpoint), you navigate using Up/Down arrows to the value, press Enter to select, then Up/Down to adjust, then Enter to confirm. When setting pressures, key parameters include: “Unload pressure”, “Max Unload”, “High tank pressure” (i.e. cutoff pressure). The manual lists typical limits: for EG-series 11 kW units, the pressure setpoints (LP) range is “7.0 to 12.5 bar” (g) for low-pressure setting in the controller. Example settings block from a Neuron II menu for such units: you might see “LP/ 7.0 to 12.5 bar” as acceptable range. ⚠️ What to be careful about / recommended safety & operational considerations The factory-set pressure and temperature settings are usually the default. Changing them incorrectly may cause performance, safety issues, or shutdowns. When stopping the compressor, you should press the STOP (red) button on controller; for emergency shutdown use the external emergency stop — don’t use emergency stop for routine stopping. After start or after adjustments, ensure that pressure sensors, solenoids, intake valve, and safety valves are functioning well (as per maintenance guidelines) — mis-adjustments or malfunction may cause “low pressure”, “unload pressure failure” or “high tank pressure” alarms. 📄 What you should do now — recommended procedure to check / adjust 1. Locate the controller panel (Neuron II) on your compressor and power it up — ensure all wiring/grounding are correct. 2. Go to main menu → “Settings” / “Parameters” → find “Pressure settings” (or similar). 3. Use Up/Down to highlight the setpoint you wish to adjust (e.g. “LP-low-pressure setpoint” or “Unload pressure”, or “Max pressure”). Press Enter. 4. Adjust within allowed range (for EG1ELGi NEURON II | Model No (EG11-150 ) ELGi Compressor AIR PESSOR UP TO DOWN Settings | EG 11 | 11kw 1 series: ~ 7.0 to 12.5 bar g) 5. Confirm with Enter. Then monitor the real-time pressure reading and ensure compressor cycles ELGi NEURON II | Model No (EG11-150 ) ELGi Compressor AIR PESSOR UP TO DOWN Settings | EG 11 | 11kw #ELGI #ELGi #ELGi NEURON #automobile #EEG 11-150 #ELGI Compressor