У нас вы можете посмотреть бесплатно Complete Diagnostic & Repair of a Dead Accuphase P-300 Power Amplifier или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
This Accuphase P-300 power amplifier arrived completely dead, presenting with multiple major failures including a blown channel, a damaged soft start circuit, faulty protection and power supply boards, and leaking main filter capacitors. Bringing it back to proper operating condition required systematic diagnostics and component-level repair across several critical sections of the amplifier. This restoration pushed my troubleshooting process further than usual, including the use of circuit simulation to identify and correct a factory error in the power supply construction. Follow along as I diagnose and repair this classic Accuphase amplifier step by step. Learn audio repair by watching me work: / novaluxstereophonic Chapters 00:00 Introduction 01:35 First Look & Soft Start Diagnosis 07:10 Testing the Power Transformer & Power Supply 11:43 Repairing the Power Supply Board 14:12 Testing the Working Channel 16:42 Repairing the Soft Start Circuit 21:41 First Power-On After Soft Start Resistor Replacement 23:36 Power Supply Service 30:00 Protection Circuit Analysis 32:46 Factory Defect Found Using EveryCircuit – 16V Supply Restored 36:57 Patreon Invitation 37:19 Rebuilding the Blown Amplifier Channel 50:46 Restoring the Lamp Flasher Function 51:29 Calibrating the Power-On Fault Detection Circuit 54:23 Baseline Distortion & Frequency Response Analysis 01:00:09 Bad Chassis Ground Causing THD & Frequency Response Issues 01:05:57 New Transistors Improve Distortion Results 01:10:53 Rebuilding the Blown Channel Again – Backwards Protection Diodes 01:15:15 Oscillation with Tektronix SG505 01:19:12 Main Filter Capacitor Replacement 01:25:00 Final DC Offset & Bias Adjustments 01:27:47 Meter Calibration 01:30:39 LED Conversion & Color Experimentation Accuphase P-300 restoration, Accuphase P-300 repair, Accuphase power amplifier repair, dead power amplifier repair, blown channel amplifier repair, vintage audio restoration, hi-fi amplifier restoration, electronic amplifier rebuild, power supply repair, protection circuit repair, soft start circuit repair, amplifier troubleshooting, bench electronics repair, component level amplifier repair, vintage hi-fi repair, audio amplifier diagnostics, transistor amplifier restoration, Accuphase amplifier service, main filter capacitor replacement, DC offset and bias adjustment YTL093