У нас вы можете посмотреть бесплатно mi-OCT guided DMEK in corneas with poor visualization - Video abstract [ID 230195] или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
Video abstract of an original research "Microscope Integrated Intra-Operative Optical Coherence Tomography Guided DMEK in Corneas with Poor Visualization” published in the open access journal Clinical Ophthalmology by Namrata Sharma, Pranita Sahay, Prafulla K. Maharana et al. Purpose:To assess the utility of microscope-integrated intraoperative optical coherence tomo-graphy (Mi-OCT) for performing Descemet membrane endothelial keratoplasty (DMEK) inncorneas with poor visualization. Methods:It is a prospective interventional case series that included 25 consecutive cases of corneal decompensation with poor visualization that underwent Mi-OCT-guided DMEK at atertiary eye care centre. The main outcome measures were graft attachment on day 3 and requirement for re-bubbling. Results:The etiology for corneal decompensation was pseudophakic bullous keratopathy (n=17),Fuchs endothelial corneal dystrophy (n=4), failed graft (n=2), iridocorneal endothelial syndrome(n=1) and failed Descemet stripping automated endothelial keratoplasty (n=1). Complete graft attachment was noted in 72% of cases. Graft detachment was noted in 16% of cases which required re-bubbling. No intervention was done for shallow peripheral detachment (n=2) and peripheral Descemet membrane (DM) fold (n=1). All grafts were attached at six-months follow-up. The mean corrected distance visual acuity and central corneal thickness improved from 1.4 ± 0.5 log MAR and 799.6 ± 110.9 μm at baseline to 0.3 ± 0.3 logMAR and 536.28 ± 11.44 um at six months. Mi-OCT was helpful in visualizing areas of peripheral anterior synechiae, missing DM, retained DM tags after descemetorhexis, DMEK roll configuration and orientation in the injector and anterior chamber, interface fluid and peripheral folds in the DMEK graft. Conclusion:Mi-OCT helps in identification of the anatomy and dynamics of the host DM,DM roll and anterior chamber in cases with poor visualization and is a useful tool while performing DMEK in such cases. Read the original article here: https://www.dovepress.com/microscope-...