У нас вы можете посмотреть бесплатно Precizon toric IOL – Video abstract ID 148599 или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
Video abstract of original research paper “Transitional conic toric intraocular lens for the management of corneal astigmatism in cataract surgery” published in the Clinical Ophthalmology journal by Bandeira F, Morral M, Elies D, et al. Synopsis: Transitional toric intraocular lens (IOL) was developed to improve refractive outcomes in cataract surgery. We report refractive, vectorial outcomes, and stability of spherical equivalent over 12 months after implantation of this IOL. Purpose: To evaluate visual and refractive outcomes of a transitional conic toric intraocular lens (IOL) (Precizon®) for the correction of corneal astigmatism in patients undergoing cataract surgery. Setting: The Ocular Microsurgery Institute (IMO), a private practice in Barcelona, Spain. Design: This is a retrospective, non-randomized study. Methods: Retrospective chart review of 156 patients with preoperative regular corneal astigmatism .0.75 diopters (D) who underwent consecutive phacoemulsification and Precizon toric IOL implantation between January 2014 and December 2015 was performed. Two groups were divided according to attempted residual refraction: group 1 with emmetropia and group 2 with mild myopia for monovision. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction were analyzed preoperatively and 3, 6, and 12 months postoperatively. Results: Precizon toric IOL was implanted in 97 eyes of 61 patients. Six months postoperatively, none of the eyes lost any line of CDVA. In all, 98% of the eyes were within ±1.00 D of attempted spherical correction. The mean preoperative keratometric cylinder was 1.92 ± 1.04 D (range 0.75–6.78), and the mean postoperative refractive cylinder was 0.77 ± 0.50 D (range 0–2.25), with 81% of the eyes with #1.00 D of residual cylinder. Two IOLs required realignment due to intraoperative positioning error. Eleven eyes required enhancement with corneal refractive surgery. Conclusion: Preexisting regular corneal astigmatism was effectively and safely corrected by the implantation of the transitional conic toric IOL in patients undergoing cataract surgery. Read the original research paper here https://www.dovepress.com/transitiona....