У нас вы можете посмотреть бесплатно Drilling procedure for UNIQA Dental Pure & Porous Implant UH8 UV11 [ 3.3 mm | D1 bone density ] или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
🦷 Uniqa Dental Drilling Protocol https://uniqa.dental/wp-content/uploads/20... 🦷 IMPORTANT! Before installing Uniqa Dental implants, it is necessary to familiarize yourself with the protocol for preparing the implant site. The video shows the sequence of operations for installing a 3.3 mm diameter implant in dense D1 bone. First, a hole should be made in the hardest cortical layer of the bone to a depth of 1-2 mm using a special cortical bone drill. Next, use a 2 mm diameter pilot drill to make the hole to full depth, typically up to 10 mm. The recommended rotational speed is 1000 rpm, maximum 1200 rpm. Drilling should be done with moderate pressure to avoid feeling resistance from the bone. Intensive irrigation is necessary to cool the drill and surrounding bone. Next, use a 2.5 mm diameter drill to go halfway into the future implant site. A 2.8 mm diameter drill can be used to go a quarter of the way into the site. Then, use a 3.2 mm drill to expand the opening of the site to the depth of the cortical bone layer, typically 2-2.2 mm. If there is resistance from the bone during drilling, it may be necessary to replace the drill as the one being used may have become dull. Under no circumstances should drilling be done without water, as this can overheat the bone and lead to thermal necrosis of the bone tissue after implant installation. Insert the implant into the prepared site. The aggressive thread profile of Uniqa Dental implants allows it to be screwed directly into the bone tissue, providing good primary stability. The maximum allowable torque when installing the implant is 50 N*cm. Carefully follow the instructions provided. Visit Uniqa Dental site https://uniqa.dental/?utm_source=youtube&u... More videos on this topic: The dental implants is placed on the smile line? • The dental implants is placed on the smile... . From a broken bar to screw retained restoration: • From a broken bar to screw retained restor... . Cemented restoration vs Screw Retained restoration in lack of space: • Cemented restoration vs Screw Retained res... . How to avoid bone loss in screw retained restoration? Using dental materials in case: • How to avoid bone loss in screw retained r... #dentalimplantsprocedure #dentalimplants #dentalimplantplacement #dentalimplantsvideo #dentalimplantprocedure #implantdrillingprocedure 🔗 Visit Uniqa Dental site https://uniqa.dental/?utm_source=youtube / 🔗 Personal-manager https://uniqa.dental/uniqa-personal-manage... 🔗 Full-Arch Restoration Workflow solution https://uniqa.dental/all-on-4-6-implants/?... Product 🦷 🔗About Test Kits https://uniqa.dental/about-trial-kits/?utm... 🔗About Implants https://uniqa.dental/uniqa-dental-implant/... 🔗Trial Kits https://uniqa.dental/trial-kits/?utm_sourc... 🔗Implants https://uniqa.dental/implants/?utm_source=... 🔗Abutments https://uniqa.dental/abutments/?utm_source... 🔗Multi-Unit Abutments https://uniqa.dental/multi-units/?utm_sour... 🔗Accessories for MUA https://uniqa.dental/accessories-for-multi... 🔗CAD/CAM https://uniqa.dental/cad-cam/?utm_source=y... 🔗Overdenture https://uniqa.dental/overdenture/?utm_sour... 🔗Laboratory https://uniqa.dental/laboratory/?utm_sourc... 🔗Instruments https://uniqa.dental/instruments/?utm_sour... 📞Customer Care: +1 737 710 17 25 📞 Logistics: +1 201 546 16 13 ✉️ Uniqa Dental Ltd 350 W Passaic St (3rd floor), Rochelle Park, NJ 07662 ✉️ 2 Ha-Tsoran St, Netanya, 4250602, Israel . ‼️ Disclaimer "The drilling protocol provided is only a general guideline and must be adapted to the individual patient, in particular to the clinical conditions, bone quality and surgeon preference. The practitioner is responsible to determine the appropriate protocol for each case based on the practitioner’s clinical knowledge, judgment and experience and the individual patient’s requirements. Uniqa Dental Ltd. does not accept any liability for any inconvenience or damage resulting from the use of the provided drilling protocol information."