• ClipSaver
ClipSaver
Русские видео
  • Смешные видео
  • Приколы
  • Обзоры
  • Новости
  • Тесты
  • Спорт
  • Любовь
  • Музыка
  • Разное
Сейчас в тренде
  • Фейгин лайф
  • Три кота
  • Самвел адамян
  • А4 ютуб
  • скачать бит
  • гитара с нуля
Иностранные видео
  • Funny Babies
  • Funny Sports
  • Funny Animals
  • Funny Pranks
  • Funny Magic
  • Funny Vines
  • Funny Virals
  • Funny K-Pop

AC Pressures, Subcooling and Superheat скачать в хорошем качестве

AC Pressures, Subcooling and Superheat 3 years ago

hvac

hvac school

AC

Pressures

Subcooling

Superheat

troubleshooting

mindset

BTrained

training

event

Birmingham

MechPic

boiling temperature

suction saturation

ambient temperature

indoor

AC systems

CFM

DTD

CTOA

SEER

ratings

BTU

TXV

HVAC system

rule of thumb

condensing

manufacturer’s specs

superheat and subcooling explained

hvac training videos

hvac basics

bryan orr

superheat and subcooling formula

hvac basics training

hvacr videos

hvac technician

metering device

Не удается загрузить Youtube-плеер. Проверьте блокировку Youtube в вашей сети.
Повторяем попытку...
AC Pressures, Subcooling and Superheat
  • Поделиться ВК
  • Поделиться в ОК
  •  
  •  


Скачать видео с ютуб по ссылке или смотреть без блокировок на сайте: AC Pressures, Subcooling and Superheat в качестве 4k

У нас вы можете посмотреть бесплатно AC Pressures, Subcooling and Superheat или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:

  • Информация по загрузке:

Скачать mp3 с ютуба отдельным файлом. Бесплатный рингтон AC Pressures, Subcooling and Superheat в формате MP3:


Если кнопки скачивания не загрузились НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу страницы.
Спасибо за использование сервиса ClipSaver.ru



AC Pressures, Subcooling and Superheat

Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in Birmingham, AL. Bryan also talks a bit about his educational photo-sharing app, MechPic. The suction pressure and suction saturation give us an idea of the refrigerant’s boiling temperature. Evaporation happens at the surface and not necessarily at the boiling temperature; on the other hand, boiling happens throughout the entire substance and occurs at the boiling temperature. So, the “evaporator” is really a heat absorber where boiling occurs. A rule of thumb for suction saturation is that it should be around 35 degrees below the indoor ambient temperature at 400 CFM per ton. That differential or temperature split, also known as the design temperature difference (DTD), is typically 30-35 degrees in high-humidity markets that use 350 CFM per ton like Florida and Alabama, where the conference took place. Lower suction pressures generally result in a higher DTD, and higher suction pressures usually result in a lower DTD. When we look at head pressure, we’re actually learning about the condensing temperature over ambient (CTOA). The CTOA is the temperature split between the outdoor ambient temperature and the condensing temperature. In general, CTOA tends to fluctuate a bit more than evaporator DTD, but a rule of thumb is that it should be about 15-20 degrees above the outdoor ambient temperature. SEER ratings may also affect CTOA. A ratio of head pressure to suction pressure is your compression ratio. Higher compression ratios tend to lead to reduced compressor performance (moving fewer BTUs). Even though we tend to see high head pressure as the main problem to avoid, we should be aware that low head pressure is possible. There needs to be an energy or pressure differential for matter to move from one place to another, and we’ll have trouble moving refrigerant if the head pressure is too low. The most important thing is to make sure that the system is working in accordance with its design. Superheat is the degrees a vapor is above its saturation temperature, and it really tells us the amount of liquid that’s stacked in the evaporator. However, the evaporator and compressor superheat could be quite different due to heat gains in the suction line. Generally, we want to see 10 degrees of evaporator superheat (+/-5 degrees) on many AC systems. The TXV is supposed to keep superheat constant; however, some possible system problems can affect superheat beyond the TXV’s control (such as significant liquid line restrictions, though there are exceptions to that example). On the other side, subcooling refers to the temperature of a liquid below its saturation temperature. In an HVAC system, subcooling indicates how much refrigerant we’ve “stacked” in the condenser; lower subcooling indicates that we have little liquid refrigerant stacked in the condenser, and higher subcooling indicates that we have a lot of liquid refrigerant stacked in the condenser. (There can, but not always, be temperature drops across liquid line restrictions.) Refrigeration systems with receivers don’t necessarily have to rely on subcooling values to indicate refrigerant storage (a rule of thumb for residential A/C systems is typically 10 degrees +/-3). When we measure subcooling, we really want to know if we’re feeding the metering device a full column of liquid. If we want to increase subcooling, we can do that by reducing the liquid temperature via mechanical subcooling or increasing the condensing temperature. (However, we don’t want too much subcooling.) When we use the manufacturer’s specs to set our superheat and subcooling, we might actually be reducing the equipment performance, so we have to know exactly what our goals are. Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/.

Comments
  • Class - What Superheat Signifies 3 years ago
    Class - What Superheat Signifies
    Опубликовано: 3 years ago
    268163
  • Refrigeration Basics with Elliot and Bert Part 1 11 months ago
    Refrigeration Basics with Elliot and Bert Part 1
    Опубликовано: 11 months ago
    102254
  • Low AC Refrigerant Charge - How to be SURE (Does it really need Freon?) 2 years ago
    Low AC Refrigerant Charge - How to be SURE (Does it really need Freon?)
    Опубликовано: 2 years ago
    183111
  • Refrigerant Overcharge Troubleshooting and Prevention 2 years ago
    Refrigerant Overcharge Troubleshooting and Prevention
    Опубликовано: 2 years ago
    207502
  • Subcooling = Stacking Liquid Refrigerant (What Subcool really Signifies) 4 years ago
    Subcooling = Stacking Liquid Refrigerant (What Subcool really Signifies)
    Опубликовано: 4 years ago
    185645
  • How To Check Superheat & Subcooling On An HVAC System 2 years ago
    How To Check Superheat & Subcooling On An HVAC System
    Опубликовано: 2 years ago
    138990
  • HVAC 101 Big review Refrigeration cycle  with all the details 3 years ago
    HVAC 101 Big review Refrigeration cycle with all the details
    Опубликовано: 3 years ago
    90367
  • Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!! 1 year ago
    Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
    Опубликовано: 1 year ago
    118967
  • The Incredible Strength of Bolted Joints 2 years ago
    The Incredible Strength of Bolted Joints
    Опубликовано: 2 years ago
    3691783
  • How to Read SUPERHEAT and SUBCOOLING 4 years ago
    How to Read SUPERHEAT and SUBCOOLING
    Опубликовано: 4 years ago
    667313

Контактный email для правообладателей: [email protected] © 2017 - 2025

Отказ от ответственности - Disclaimer Правообладателям - DMCA Условия использования сайта - TOS