They installed a brand new Weil-McLain gas fired steam boiler… and then added ONE air valve in the wrong location — turning the entire dry return into a steam main. The result? Massive pipe banging. Violent water hammer. An unbalanced system. Angry homeowners. In this service call in Marine Park, Brooklyn (NYC area) — just outside our typical Long Island service territory — I explain exactly why adding a steam main vent to a dry return completely destroys system balance. Steam systems are simple… IF you respect pressure and venting. When someone gets creative and installs a main vent where steam was NEVER supposed to exist… you turn condensate piping into a steam highway. 💥 Steam meets standing water. 💥 Explosive collapse. 💥 BANG. This video is for: • Steam heating technicians • Plumbing & HVAC pros • Homeowners with banging radiators • Anyone who thinks “more venting is always better” Respect the Dead Men. Respect the design. 📍 SERVING LONG ISLAND, NY If your steam boiler is banging, short cycling, over-pressurizing, or installed incorrectly: 📞 Pipe Doctor Home Services 516-348-6300 🌐 https://pipedoc.net We specialize in steam heating systems across Long Island, NY. 🔧 ARE YOU A LICENSED HVAC CONTRACTOR? Want access to private-label inverter heat pumps? 👉 Become an official ACiQ dealer here: https://aciq.com/mikeypipes Dealer portal access. No commitment to buy. NDA required. Keep it simple. 🎯 LIMITED EDITION 2025 MIKEY PIPES POSTER – $42.50 100% of proceeds go to charity. Includes: • 5 stickers • Collector card • Magnet PayPal: mike@mikeypipes.com Venmo: @PipeDoctor CashApp: $mikeypipesny Zelle: mike@mikeypipes.com Thank you for supporting Mikey Pipes Philanthropy. ⏱ CHAPTERS 0:00 The Email That Started It 1:12 Outside My Service Area (But We Went Anyway) 2:45 First Look at the Weil-McLain Install 4:10 The “Creative” Air Valve Placement 6:20 Why the Dry Return Became a Steam Main 8:05 Combustion Analysis & Boiler Pressure 10:30 Why It’s Banging So Bad 13:20 Steam + Standing Water = EXPLOSIVE Collapse 15:00 Final Diagnosis & Lesson for Techs Steam heating systems were a PREMIUM upgrade 80–100 years ago. They were whisper quiet when installed properly. If your system is loud… someone touched something they shouldn’t have. Smash that 👍 Subscribe if you’re serious about mastering the trades. Comment below: Have you ever seen a vent added where it didn’t belong? #️⃣ Hashtags #SteamHeating #WaterHammer #HVACTraining