• ClipSaver
ClipSaver
Русские видео
  • Смешные видео
  • Приколы
  • Обзоры
  • Новости
  • Тесты
  • Спорт
  • Любовь
  • Музыка
  • Разное
Сейчас в тренде
  • Фейгин лайф
  • Три кота
  • Самвел адамян
  • А4 ютуб
  • скачать бит
  • гитара с нуля
Иностранные видео
  • Funny Babies
  • Funny Sports
  • Funny Animals
  • Funny Pranks
  • Funny Magic
  • Funny Vines
  • Funny Virals
  • Funny K-Pop

What is Sensor Calibration and Why is it Important? скачать в хорошем качестве

What is Sensor Calibration and Why is it Important? 6 years ago

Sensor Calibration

Instrument Calibration

Sensor Measurement

Sensor Adjustment

Zero and Span Adjustment

Analogue Sensor Calibration

Sensor Error Measurement

As Found Values

Five-Point Check

Deviation Graph

Sensor Calibration Sheet

Sensor Calibration Chart

Zero Adjustment

Span Adjustment

Sensor Trim

4-20 mA trim

Hand Pump

Sensor Measurement Hysteresis

Hand Held Communicator

Не удается загрузить Youtube-плеер. Проверьте блокировку Youtube в вашей сети.
Повторяем попытку...
What is Sensor Calibration and Why is it Important?
  • Поделиться ВК
  • Поделиться в ОК
  •  
  •  


Скачать видео с ютуб по ссылке или смотреть без блокировок на сайте: What is Sensor Calibration and Why is it Important? в качестве 4k

У нас вы можете посмотреть бесплатно What is Sensor Calibration and Why is it Important? или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:

  • Информация по загрузке:

Скачать mp3 с ютуба отдельным файлом. Бесплатный рингтон What is Sensor Calibration and Why is it Important? в формате MP3:


Если кнопки скачивания не загрузились НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу страницы.
Спасибо за использование сервиса ClipSaver.ru



What is Sensor Calibration and Why is it Important?

✅ C'mon over to https://realpars.com where you can learn PLC programming faster and easier than you ever thought possible! ============================= ✅ Check out the full blog post over at https://realpars.com/sensor-calibration/ ============================= When engineers design modern process plants, they specify sensors to measure important process variables, such as flow, level, pressure, and temperature. These measurements are used to help the process control system adjust the valves, pumps and other actuators in the plant to maintain the proper values of these quantities and to ensure safe operation. So how does a plant maintain the operation of these sensors to guarantee that the actual value of the process is sensed and passed to the control system? In this video, you will learn that the answer to that question is: “Sensor Calibration”. Sensor calibration is an adjustment or set of adjustments performed on a sensor or instrument to make that instrument function as accurately, or error-free, as possible. An error is simply the algebraic difference between the indication and the actual value of the measured variable. Errors in sensor measurement can be caused by many factors. First, the instrument may not have a proper zero reference. Modern sensors and transmitters are electronic devices, and the reference voltage, or signal, may drift over time due to temperature, pressure, or change in ambient conditions. Second, the sensor’s range may shift due to the same conditions just noted, or perhaps the operating range of the process has changed. For example, a process may currently operate in the range of 0 to 200 pounds per square inch, but changes in operation will require it to run in the range of 0 to 500 pounds per square inch. Third, error in sensor measurement may occur because of mechanical wear, or damage. Usually, this type of error will require repair or replacement of the device. Errors are not desirable since the control system will not have accurate data from which to make control decisions, such as adjusting the output of a control valve or setting the speed of a feed pump. If the calibration is too far from the accurate process conditions, process safety may be jeopardized. To perform an “as-found” check, an accurate and precise instrument is used to develop process signals corresponding to 0%, 25%, 50%, 75% and 100% of the process range of the transmitter. The corresponding transmitter output, in milliamps, is observed and recorded. This is called a “5-point” check. Then, in order to check for hysteresis, a phenomenon whereby the sensor output for a process value is different going 'downscale' as it is going 'upscale', the output signals corresponding to 100%, 75%, 50%, 25%, and 0% in order are recorded. The deviations at each checkpoint are calculated and compared to the deviation maximum allowed for the device. If the deviation is greater than the maximum allowed, then a full calibration is performed. If the deviation is less than the maximum allowed, then a sensor calibration is not required. If we have an analog transmitter, we must adjust zero and span to reduce the measurement error. With an analog transmitter, there is a ZERO and SPAN adjustment on the transmitter itself. Zero adjustment is made to move the output to exactly 4 milliamps when a 0% process measurement is applied to the transmitter, and the Span adjustment is made to move the output to exactly 20 milliamps when a 100% process measurement is applied. Unfortunately, with analog transmitters, the zero and span adjustments are interactive; that is, adjusting one moves the other. Therefore, the calibration is an iterative process to set zero and span, but only 2 to 3 iterations are usually required. ============================= Missed our most recent videos? Watch them here: https://realpars.com/ethernet/ https://realpars.com/fieldbus/ https://realpars.com/function-block/ ============================= To stay up to date with our last videos and more lessons, make sure to subscribe to this YouTube channel: http://goo.gl/Y6DRiN ============================= TWEET THIS VIDEO https://ctt.ac/enA08 ============================= Like us on Facebook:   / therealpars   Follow us on Twitter:   / realpars   Follow us on LinkedIn   / realpars  

Comments
  • What is HART Protocol? 6 years ago
    What is HART Protocol?
    Опубликовано: 6 years ago
    1050236
  • Reviewing the Basics of an Electrical Control Panel (Practical Example) 5 years ago
    Reviewing the Basics of an Electrical Control Panel (Practical Example)
    Опубликовано: 5 years ago
    358406
  • Caliper Calibration - How to Calibrate a Caliper 6 years ago
    Caliper Calibration - How to Calibrate a Caliper
    Опубликовано: 6 years ago
    199033
  • Variable Frequency Drives Explained - VFD Basics IGBT inverter 5 years ago
    Variable Frequency Drives Explained - VFD Basics IGBT inverter
    Опубликовано: 5 years ago
    3410685
  • Music for Work — Deep Focus Mix for Programming, Coding 5 months ago
    Music for Work — Deep Focus Mix for Programming, Coding
    Опубликовано: 5 months ago
    516639
  • Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Transcat 5 years ago
    Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Transcat
    Опубликовано: 5 years ago
    59431
  • How to Wire Discrete DC Sensors to PLC - Part 2 6 years ago
    How to Wire Discrete DC Sensors to PLC - Part 2
    Опубликовано: 6 years ago
    324254
  • Calibration of rosemount 3144p pt1 thermocouple 5 years ago
    Calibration of rosemount 3144p pt1 thermocouple
    Опубликовано: 5 years ago
    146747
  • What is a Level Sensor? 5 years ago
    What is a Level Sensor?
    Опубликовано: 5 years ago
    531055
  • How to Wire Discrete DC Sensors to PLC - Part 1 6 years ago
    How to Wire Discrete DC Sensors to PLC - Part 1
    Опубликовано: 6 years ago
    353286

Контактный email для правообладателей: [email protected] © 2017 - 2025

Отказ от ответственности - Disclaimer Правообладателям - DMCA Условия использования сайта - TOS