У нас вы можете посмотреть бесплатно How to check torsional irregularity in building using etabs или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
ETABS PROFESSIONAL COURSE JOIN NOW USING PROMO LINK ONLY FOR EXCLUSIVE CONTENT AND COMPLETE 20 STORY BUILDING DESIGN WORKSHOP: https://www.udemy.com/course/etabs-rc... ETABS Playlist: • Видео SAP2000 tutorials : • Видео IMRF Design : • RCC Column Design using etabs tutorial – I... How to check torsional irregularity in building using etabs Torsional irregularity check in etabs Check for torsion limit in etabs Check for overturning in etabs How to check overturning in etabs Provision shall be made for the increased forces induced on resisting elements of the structural system resulting from torsion due to eccentricity between the center of application of the lateral forces and the center of rigidity of the lateral-force-resisting system. For accidental torsion requirements for seismic design Stability against overturning. Every structure shall be designed to resist the overturning effects caused by the lateral forces . Horizontal Torsional Moments. Provisions shall be made for the increased shears resulting from horizontal torsion where diaphragms are not flexible. The most severe load combination for each element shall be considered for design. The torsional design moment at a given story shall be the moment resulting from eccentricities between applied design lateral forces at levels above that story and the vertical-resisting elements in that story plus an accidental torsion. The accidental torsional moment shall be determined by assuming the mass is displaced . Where torsional irregularity exists, the effects shall be accounted for by increasing the accidental torsion at each level by an amplification factor Torsional irregularity to be considered when diaphragms are not flexible Torsional irregularity shall be considered to exist when the maximum story drift, computed including accidental torsion, at one end of the structure transverse to an axis is more than 1.2 times the average of the story drifts of the two ends of the structure. How to fix overturning in building Fix torsion irregularity How to resolve torsional irregularity in building design #etabs #engineering #design