P&ID check list: 1.General: -Title Box according to Project requirements -Complex / plant / equipment number and tag -Compliance with Project Specifications and Client Std -Cross-references between P&ID -Package Battery Limit arrangement -Consistency with tie-in list -Uniformity of symbols, general notes and standard details -Hold Index -Consistency with PFD s, MSD s and Item List -Conformity with equipment data sheets -Main control systems (operating mode, control strategy) -Special equipment / package control systems -Emergency isolation of plant unit: Emergency Shut Down (ESD) and Emergency Depressurization (EDP) requirements -Installation of safety systems: pressure safety valve (PSV), depressurization, process trip 2. Piping: -Consistency with Fluid lists, MSD s and safeguarding requirements -Piping operating and design conditions -Piping class identification -Identification of material break and pressure class -Consistency of diameters, ratings, materials, corrosion allowance of lines, internal lining, cladding, and special alloy -Insulation (Hot Conservation, Cold Conservation, Personnel -Protection) and heat tracing (steam / electric) requirements -Drain / vent to open system (gravity flow) / closed (pressurized) system -Purge connections -Mixed phase in vertical/horizontal pipes and related note for mixed flow lines support -Gravity-flow, slope and pocket number identification/indication -Line layout and symmetry (column / vessel feed lines, compressor suction / discharge lines, anti-surge lines, header arrangement for parallel equipment) -Backflow /Reverse flow identification -Installation of filters to protect rotameters, PCV s and minor components -Injection of chemicals if required by process conditions (hydrate inhibitors, antifoam agents, demulsifier, corrosion and scale inhibitors) -Identification of tie-ins -Positive Isolation (spectacle blind SB, spacer ring SP, removable spool RSP, blind, spade) for piping systems (in/out unit and common system) -Manual block valve selection type (which one): ball, globe, gate, butterfly, plug valves -Manual block valve isolation/installation philosophy (how, when, where): critical location, frequency of operation -Check valve / Non Return Valves type selection (standard swing, non slam, low pressure drop, anti-stuck, Tight Shut Off) and isolation/installation philosophy 3. Instrumentation: -Instrument protection for adverse process and ambient environments (as for Company standard or API 551, section 6.1) "Level instrument for vent and drain (as for Company standard or API 551, section 3.2.9)" -Location of flow measurement devices -Control system functionality -Provision of instruments for test run 4. Control Valves: -Control valve sizing and specific location -Control valve installation (avoid inlet mixed phase) -Formation of hydrates downstream of control valves -Flow element up/down stream distance requirements 5. Safety Relief System -Risk evaluation/protective measures for Loss of containment, Pool fire, Jet fire, BLEVE (boiling liquid expanding vapour explosion -Pressure safety valves (PSV) requirements (API 521), sizing case and set pressure -Pressure safety valves installation (main, spare) and isolation (full bore, locked open, car seal open, interlock) (how and where) -Automatic block valves isolation/installation philosophy for Safety System (Emergency Shutdown Valve ESDV, Blow Down Valve BDV, Shutdown Valve SDV, On-Off Shutdown Valve XV) -Fail safe position, Tight Shut Off, fireproofing, logic interlock standard installation arrangement -Plant units and/or plant unit start-up and shutdown conditions Systems for flushing, cleaning, blowing, purging and defrosting of plant units -Plant / units isolation for maintenance Implementation of major changes due to tender bulletins and answers to queries -Implementation of design modification requested from the Client after Technical/Commercial proposal (if any) -Implementation of Lessons Learned -Consistency with HAZOP and SIL recommendations / requirements 6. Vessels: -Consistency with Process / Mechanical Data Sheet (instrument connections, operating/design conditions, etc.) and General Arrangement dwg." -Vent, Drain, UC (Purge/Steam-Out) connected to equipment (temporary/permanent – Hose/Hard-piped) -Sizing and numbers of Manholes, Top-Flanged and other inspection opening -Elevation from ground level (absolute) or from other equipment (relative) e.g. reboiler for column -Internal pattern of chemical injection nozzles -Internals (demister, plate pack), details of trays path/packing, draw off and distributors, settle out, weirs (for separator). -Identify storage classification considered in tank design (Atm, LP, MP, refrigerated/heated or cryogenic) and provide typical accessories and facilities arrangement -Pressure Vacuum Control and relief system PVSV