У нас вы можете посмотреть бесплатно Blustream PDU Demo @ ISE 2026 – Intelligent Power Management Solutions или скачать в максимальном доступном качестве, видео которое было загружено на ютуб. Для загрузки выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием видео, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса ClipSaver.ru
Demonstration of Blustream's PDU (Power Distribution Unit) product range, presented by Aiden, Technical Director EMEA at ISE 2026 Barcelona. This presentation was delivered to the team from NTNU Section for Teaching, Learning and Digital Services. 🔗 Product Info: https://www.blustream.co.uk/power-man... 🎓 NTNU Digital Services: https://www.ntnu.edu/adm/edudivision/sld ⏱️ TIMESTAMPS: 00:04 – Introduction: Blustream PDU Range Overview 00:16 – Product Lineup: 3 Current + 2 Coming Soon 00:23 – IEC Mains PDU: 8-Way, 4-Way, 2-Way Options 00:37 – 8-Way Vertical Strip Mount (Coming Soon) 00:51 – Technical Specs: 16A (8-way), 10A (smaller models) 00:56 – Voltage Range: 110V-264V Universal 01:03 – Independent Outlet Control via API 01:13 – Overload & Surge Protection 01:18 – Interference Filtering 01:24 – Auto-Reboot After Power Cuts 01:29 – Scheduling Capabilities 01:35 – Sequential Power-On with Custom Delays 01:49 – Network Equipment Boot Sequencing Example 02:03 – Dual Redundant Network Ports 02:17 – Sensor Ports (8-Way Models) 02:22 – Environmental Monitoring: Movement, Humidity, Temperature 02:28 – Building Management System Integration 02:40 – Front Panel Physical Controls 02:51 – Low Voltage PDU Introduction 02:58 – Multi-Voltage Outputs: 5V, 9V, 12V, 18V, 24V 03:05 – Independent Voltage Configuration Per Outlet 03:12 – Fine-Tuning: ±1V Adjustment 03:25 – Use Case: Eliminating Wall Wart Transformers 03:47 – Remote Monitoring & Scheduling 03:57 – Per-Channel Voltage Monitoring 04:09 – Power Monitoring: Current, Voltage, Energy, Power Factor 04:21 – Integration Protocols: SNMP, Modbus, TailNet, MQTT 04:34 – XYTE Platform Integration Announcement 04:56 – Watchdog Function (New Feature) 05:06 – IP-Based Equipment Monitoring 05:12 – Auto-Ping & Auto-Reboot Functionality 05:22 – Network State-Based Automation 05:38 – Email Alerts: Surge, Power Cut Notifications 05:48 – Multi-Recipient Email (Up to 3 Addresses) 06:00 – 24/7 Scheduling for Energy Savings 06:14 – Summary: Available & Coming Soon Products 🔧 KEY FEATURES DEMONSTRATED: ✅ IEC Mains PDU: 8-way (16A), 4-way (10A), 2-way (10A) ✅ 8-way vertical strip mount (coming Q2) ✅ Universal voltage: 110V-264V ✅ Independent outlet control via API ✅ Overload, surge protection & interference filtering ✅ Auto-reboot after power cuts ✅ Sequential power-on scheduling ✅ Dual redundant network ports ✅ Environmental sensors (temperature, humidity, movement) ✅ Building management system integration ✅ Low voltage PDU: 5V, 9V, 12V, 18V, 24V outputs ✅ ±1V fine-tuning per outlet ✅ Real-time monitoring: current, voltage, energy, power factor ✅ SNMP, Modbus, TailNet, MQTT integration ✅ XYTE platform support ✅ Watchdog function with IP monitoring ✅ Email alerts (up to 3 recipients) ✅ 24/7 scheduling for energy management 💼 USE CASES: AV rack power management Network equipment boot sequencing Eliminating wall wart transformers Remote equipment monitoring and rebooting Energy savings in corporate environments Environmental monitoring in server rooms Building management integration Educational institution AV systems 🎯 TECHNICAL CAPABILITIES: 8-way: 16A capacity 4-way & 2-way: 10A capacity Voltage range: 110V-264V Low voltage options: 5V-24V (±1V adjustable) Dual redundant network ports Sensor ports for temperature/humidity/movement API control & automation SNMP traps, Modbus, TailNet, MQTT protocols Watchdog IP ping monitoring Email notifications 📍 ISE 2026 (Integrated Systems Europe), Barcelona Presented to NTNU Section for Teaching, Learning and Digital Services