Hydro test failed repeteadly- Do STEP TEST to clear Doubts. If a hydrostatic (hydro) test is failing repeatedly, it's crucial to diagnose the root cause systematically. A hydrostatic test assesses the integrity of a system, such as a pipeline, pressure vessel, or tank, by filling it with water or another incompressible fluid under pressure. Here's how to approach the issue: 1. *Check for Visible Leaks* Inspect the test area for visible leaks, cracks, or water dripping. Use dye or tracer in the water to identify hard-to-spot leaks. 2. *Verify Test Setup* **Connections**: Ensure all fittings, valves, and connections are properly sealed and tightened. **Instrumentation**: Check if gauges, pressure transducers, and other measurement tools are functioning correctly and calibrated. 3. *Test Procedures* Confirm that the test is being conducted according to industry standards (e.g., ASME, API, ISO). Verify that the system is fully vented to remove all trapped air, as air pockets can cause erratic pressure readings. 4. *Material Weakness* Look for weak points in welds, joints, or the material itself. Conduct non-destructive testing (NDT) methods like ultrasonic testing or radiographic inspections to detect cracks or flaws. 5. *Pressure Drop Analysis* Monitor pressure decay over time. If pressure drops: **Rapidly**: Likely a significant leak or failure. **Slowly**: Could be a small leak or thermal effects (temperature changes causing pressure variations). 6. *Temperature Effects* Ensure consistent water and ambient temperatures. Thermal expansion or contraction can influence test results. 7. *Contamination* Check for debris, rust, or other contaminants that might interfere with sealing or cause micro-leaks. 8. *Re-test Strategy* After addressing potential issues, re-conduct the test systematically. Consider isolating sections of the system to pinpoint the problem area. 9. *Consult Experts* If issues persist, engage a professional engineer or third-party inspector to review the system design, materials, and test methodology. Would you like guidance on a specific part of your hydro test setup or troubleshooting process?